|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
A
AdvFS
backing up disks
ASE
adding network interfaces
backing up disks
description of
description of services
disk service
examples of
maintaining CPU
maintaining disks
maintaining hardware
NFS service
overview
planning
planning
removing network interfaces
restoring disks
services
starting activity
stopping activity
tape service
types of services
user-defined service
Asynchronous Transfer Mode
See ATM
ATM
atmconfig command
connecting cables
installation
Lan Emulation (LANE)
LANE
atmconfig command
availability
increasing
available server environment
See ASE
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
B
BA350
BA350 storage shelf
preparing
BA353
BA353 storage shelf
preparing
BA356
jumper
jumper
jumper
termination
termination
termination
backing up ASE disks
bus hung message
bus speed
displaying
buses
data paths
differential
extending differential
naming
narrow data path
numbering
numbering
selecting SCSI port or channel
single-ended
speed
terminating
terminating
terminating
wide data path
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
C
cable
BC12N-10
BC39B-04
BC39B-10
cables
See SCSI cables
cabling
DS-TZ89N-TA
DS-TZ89N-VW
TZ885
TZ88N-TA
TZ88N-VA
cluster
changing the configuration
expanding
expanding
expanding
figures
four-member system configuration
increasing availability
one-ASE configuration
planning
shutting down
starting cluster daemons
starting up
stopping cluster daemons
supported hardware
system does not have to be in an ASE
three-member system configuration
two-ASE configuration
two-member system configuration
Cluster interconnects:
increasing availability
command
show config
show device
show device
show pk#*
show pk#*
t, for TURBOchannel devices
commands
atmconfig
connectors
supported
CPU maintenance
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
D
daemons
stopping
data path
for buses
DEC RAID subsystem array controllers
preparing
DEC RAID subsystem controllers
using in ASE
devices
displaying
differential SCSI buses
description of
differential transmission
definition
DIGITAL Linear Tape
See DLT
disk devices
adding
backing up
handling failures
maintaining
maintaining
removing
requirements
restoring
setting on and off line
setting up
supported
using LSM
using RAID
disk service
applications in
database program in
description of
description of
IP address for
displaying device information
KZPSA
distributed lock manager
See DLM
Distributed Raw Disk
See DRD
DLM
DLT
TZ88
TZ885
TZ885
TZ89
documentation
HTML versions of
DRD
DRD service
description of
DS-TZ89N-TA
cabling
setting SCSI ID
DS-TZ89N-VW
cabling
setting SCSI ID
DWZZA
incorrect hardware revision
installed in BA353
termination
DWZZA signal converters
See SCSI signal converters
DWZZA upgrade
DWZZB
termination
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
F
firmware
displaying revisions
obtaining release notes
reset system for update
update CD-ROM
updating
updating KZPSA
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
H
hardware components
disk devices
member systems
MEMORY CHANNEL hardware
RAID controllers
SCSI adapters
SCSI cables
SCSI signal converters
SCSI terminators
storage shelves
trilink connectors
hardware configuration
bus termination
changing
description of
disk devices
examples
hardware requirements for
introduction to
maintaining
making more highly available
network adapters
network adapters
requirements
SCSI bus adapters
SCSI bus speed
SCSI cables
SCSI signal converters
storage shelves
supported devices
terminators
trilink connectors
two-bus configuration
HSZ10 controllers
and shared SCSI bus
HSZ20 controllers
and shared SCSI bus
HSZ40 controllers
and shared SCSI bus
HSZ50 controllers
and shared SCSI bus
HSZ70
and fast wide differential SCSI
HSZ70 controllers
and shared SCSI bus
HTML
documentation in
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
I
installation
ATM adapter
KZPSA
MEMORY CHANNEL
MEMORY CHANNEL cables
MEMORY CHANNEL hub
installing hardware
See hardware configuration
IP host name
for a disk service
for an NFS service
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
J
jumpers
MEMORY CHANNEL
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
K
KZMSA
boot ROM revision
setting BUS ID
setting bus speed
trucluster configuration
KZMSA adapters
chips supported
requirements
KZPSA
determining bus speed
determining firmware revision
determining SCSI ID
displaying device information
installation
setting bus speed
setting SCSI ID
termination resistors
updating firmware
use with TruCluster
KZPSA adapters
requirements
KZTSA
jumpers
setting bus speed
setting SCSI ID
trucluster configuration
KZTSA adapters
requirements
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
L
LAN Emulation
See LANE
LANE
LFU
LFU
booting
booting
starting
updating firmware
updating KZMSA
use with DEC 7000 or DEC 10000
link cable
installation
Loadable Firmware Update utility
See LFU
Logical Storage Manager
See LSM
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
M
member
of cluster but not of an ASE
member systems
adding
CPU maintenance
definition of
definition of
displaying configuration information
improving performance
increasing availability
maintaining
removing
requirements
shutting down
supported
MEMORY CHANNEL
installation
installation
interconnect
jumpers
MEMORY CHANNEL hub
installation
MEMORY CHANNEL interconnects
adding
adding a hub
connecting adapters to a hub
disconnecting link cables
displaying primary
maintaining
removing
replacing a hub
requirements
requirements
setting up
MEMORY CHANNEL PCI adapter
supported hardware
message
bus hung
MMF
multimode fiber optic
See MMF
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
N
network adapters
ATM
networks
adding
removing
supported ATM adapters
supported Ethernet adapters
NFS service
description of
description of
using IP host name for
non-Ultra BA356 storage shelf
preparing
numbering SCSI buses
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
O
OPS
Oracle Parallel Server
See OPS
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
P
performance
improving
personality module
See signal converters
planning the hardware configuration
PMAZC
jumpers
requirements
setting bus speed
setting SCSI ID
trucluster configuration
POLYCENTER Advanced File System
See AdvFS
POLYCENTER NetWorker
using for services
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
R
RAID controllers
and shared SCSI bus
supported
requirements
HSZ10 controllers
HSZ40 controllers
KZMSA adapters
KZPSA adapters
KZTSA adapters
PMAZC
SCSI bus
restoring ASE disks
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
S
SCSI
number of devices supported
SCSI bus adapters
supported
SCSI bus ID
displaying
SCSI buses
See shared SCSI buses
SCSI cables
requirement
supported
SCSI controllers
bus speed for
numbering
selecting SCSI port or channel
SCSI IDs
BA350 storage shelves
BA353 storage shelves
BA356 storage shelves
DEC RAID subsystem controllers
HSZ10 DEC RAID controllers
HSZ20 DEC RAID controllers
HSZ40 DEC RAID controllers
HSZ50 DEC RAID controllers
HSZ70 DEC RAID controllers
requirement
SCSI terminators
supported
SCSI-2 bus
services
description of
description of
setting bus speed
KZPSA
setting SCSI ID
DS-TZ89N-TA
DS-TZ89N-VW
KZPSA
TZ885
TZ88N-TA
TZ88N-VA
Shared SCSI
adding devices
shared SCSI buses
adding
assigning SCSI IDs
cable length restrictions
connecting devices
connecting devices
device addresses
differential
removing
requirements
setting up ASEs
single-ended
using SCSI signal converters
using trilink connectors
using Y cables
shared storage
BA350 storage shelf
BA353 storage shelf
DEC RAID subsystem array controller
increasing capacity
increasing capacity
non-Ultra BA356 storage shelf
Ultra BA356 storage shelf
signal converter
DS-BA35X-DA personality module
signal converters
connecting and disconnecting
creating differential bus
differential I/O module
differential termination
DS-BA35X-DA
extending differential bus length
fast SCSI bus speed
overview
requirement
requirements
SBB
single-ended termination
standalone
supported
terminating
terminating buses with
termination
termination
using in ASE
using in ASE
single-ended SCSI buses
description of
single-ended transmission
definition
Small Computer System Interconnect
See SCSI
storage shelves
adding
BA350
BA353
BA356
removing
requirements
setting up
supported
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
T
tape service
description of
description of
terminating the shared bus
termination resistors
KZPSA
trilink connectors
connecting devices with
requirement
supported
terminating bus with
TruCluster Software Products
MEMORY CHANNEL
TruCluster Available Server Software
TruCluster Production Server Software
TZ88
TZ88
versions
TZ885
TZ885
cabling
setting SCSI ID
TZ88N-TA
cabling
setting SCSI ID
TZ88N-VA
cabling
setting SCSI ID
TZ89
TZ89
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
U
Ultra BA356 storage shelf
preparing
UltraSCSI BA356
fast narrow SCSI drives
fast wide SCSI drives
personality module (DS-BA35X-DA)
power supply
UltraSCSI host adapater
host input connector
with non-UltraSCSI BA356
with UltraSCSI BA356
unshielded twisted pair
See UTP
upgrade
DWZZA
user-defined service
description of
description of
UTP
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
V
Very High Density Cable Interconnect
See VHDCI
VHDCI
HSZ70 host connector
mnemonics defined
|
Click letter for quick access: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z |
Y
Y cables
connecting devices with