[Contents] [Help]

Index

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

A

AdvFS
        backing up disks

ASE
        adding network interfaces
        backing up disks
        description of
        description of services
        disk service
        examples of
        maintaining CPU
        maintaining disks
        maintaining hardware
        NFS service
        overview
        planning
        planning
        removing network interfaces
        restoring disks
        services
        starting activity
        stopping activity
        tape service
        types of services
        user-defined service

Asynchronous Transfer Mode
        See ATM

ATM
        atmconfig command
        connecting cables
        installation
        Lan Emulation (LANE)
        LANE

atmconfig command

availability
        increasing

available server environment
        See ASE

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

B

BA350

BA350 storage shelf
        preparing

BA353

BA353 storage shelf
        preparing

BA356
        jumper
        jumper
        jumper
        termination
        termination
        termination

backing up ASE disks

bus hung message

bus speed
        displaying

buses
        data paths
        differential
        extending differential
        naming
        narrow data path
        numbering
        numbering
        selecting SCSI port or channel
        single-ended
        speed
        terminating
        terminating
        terminating
        wide data path

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

C

cable
        BC12N-10
        BC39B-04
        BC39B-10

cables
        See SCSI cables

cabling
        DS-TZ89N-TA
        DS-TZ89N-VW
        TZ885
        TZ88N-TA
        TZ88N-VA

cluster
        changing the configuration
        expanding
        expanding
        expanding
        figures
        four-member system configuration
        increasing availability
        one-ASE configuration
        planning
        shutting down
        starting cluster daemons
        starting up
        stopping cluster daemons
        supported hardware
        system does not have to be in an ASE
        three-member system configuration
        two-ASE configuration
        two-member system configuration

Cluster interconnects:
        increasing availability

command
        show config
        show device
        show device
        show pk#*
        show pk#*
        t, for TURBOchannel devices

commands
        atmconfig

connectors
        supported

CPU maintenance

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

D

daemons
        stopping

data path
        for buses

DEC RAID subsystem array controllers
        preparing

DEC RAID subsystem controllers
        using in ASE

devices
        displaying

differential SCSI buses
        description of

differential transmission
        definition

DIGITAL Linear Tape
        See DLT

disk devices
        adding
        backing up
        handling failures
        maintaining
        maintaining
        removing
        requirements
        restoring
        setting on and off line
        setting up
        supported
        using LSM
        using RAID

disk service
        applications in
        database program in
        description of
        description of
        IP address for

displaying device information
        KZPSA

distributed lock manager
        See DLM

Distributed Raw Disk
        See DRD

DLM

DLT
        TZ88
        TZ885
        TZ885
        TZ89

documentation
        HTML versions of

DRD

DRD service
        description of

DS-TZ89N-TA
        cabling
        setting SCSI ID

DS-TZ89N-VW
        cabling
        setting SCSI ID

DWZZA
        incorrect hardware revision
        installed in BA353
        termination

DWZZA signal converters
        See SCSI signal converters

DWZZA upgrade

DWZZB
        termination

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

F

firmware
        displaying revisions
        obtaining release notes
        reset system for update
        update CD-ROM
        updating
        updating KZPSA

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

H

hardware components
        disk devices
        member systems
        MEMORY CHANNEL hardware
        RAID controllers
        SCSI adapters
        SCSI cables
        SCSI signal converters
        SCSI terminators
        storage shelves
        trilink connectors

hardware configuration
        bus termination
        changing
        description of
        disk devices
        examples
        hardware requirements for
        introduction to
        maintaining
        making more highly available
        network adapters
        network adapters
        requirements
        SCSI bus adapters
        SCSI bus speed
        SCSI cables
        SCSI signal converters
        storage shelves
        supported devices
        terminators
        trilink connectors
        two-bus configuration

HSZ10 controllers
        and shared SCSI bus

HSZ20 controllers
        and shared SCSI bus

HSZ40 controllers
        and shared SCSI bus

HSZ50 controllers
        and shared SCSI bus

HSZ70
        and fast wide differential SCSI

HSZ70 controllers
        and shared SCSI bus

HTML
        documentation in

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

I

installation
        ATM adapter
        KZPSA
        MEMORY CHANNEL
        MEMORY CHANNEL cables
        MEMORY CHANNEL hub

installing hardware
        See hardware configuration

IP host name
        for a disk service
        for an NFS service

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

J

jumpers
        MEMORY CHANNEL

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

K

KZMSA
        boot ROM revision
        setting BUS ID
        setting bus speed
        trucluster configuration

KZMSA adapters
        chips supported
        requirements

KZPSA
        determining bus speed
        determining firmware revision
        determining SCSI ID
        displaying device information
        installation
        setting bus speed
        setting SCSI ID
        termination resistors
        updating firmware
        use with TruCluster

KZPSA adapters
        requirements

KZTSA
        jumpers
        setting bus speed
        setting SCSI ID
        trucluster configuration

KZTSA adapters
        requirements

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

L

LAN Emulation
        See LANE

LANE

LFU
LFU
        booting
        booting
        starting
        updating firmware
        updating KZMSA
        use with DEC 7000 or DEC 10000

link cable
        installation

Loadable Firmware Update utility
        See LFU

Logical Storage Manager
        See LSM

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

M

member
        of cluster but not of an ASE

member systems
        adding
        CPU maintenance
        definition of
        definition of
        displaying configuration information
        improving performance
        increasing availability
        maintaining
        removing
        requirements
        shutting down
        supported

MEMORY CHANNEL
        installation
        installation
        interconnect
        jumpers

MEMORY CHANNEL hub
        installation

MEMORY CHANNEL interconnects
        adding
        adding a hub
        connecting adapters to a hub
        disconnecting link cables
        displaying primary
        maintaining
        removing
        replacing a hub
        requirements
        requirements
        setting up

MEMORY CHANNEL PCI adapter
        supported hardware

message
        bus hung

MMF

multimode fiber optic
        See MMF

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

N

network adapters
        ATM

networks
        adding
        removing
        supported ATM adapters
        supported Ethernet adapters

NFS service
        description of
        description of
        using IP host name for

non-Ultra BA356 storage shelf
        preparing

numbering SCSI buses

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

O

OPS

Oracle Parallel Server
        See OPS

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

P

performance
        improving

personality module
        See signal converters

planning the hardware configuration

PMAZC
        jumpers
        requirements
        setting bus speed
        setting SCSI ID
        trucluster configuration

POLYCENTER Advanced File System
        See AdvFS

POLYCENTER NetWorker
        using for services

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

R

RAID controllers
        and shared SCSI bus
        supported

requirements
        HSZ10 controllers
        HSZ40 controllers
        KZMSA adapters
        KZPSA adapters
        KZTSA adapters
        PMAZC
        SCSI bus

restoring ASE disks

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

S

SCSI
        number of devices supported

SCSI bus adapters
        supported

SCSI bus ID
        displaying

SCSI buses
        See shared SCSI buses

SCSI cables
        requirement
        supported

SCSI controllers
        bus speed for
        numbering
        selecting SCSI port or channel

SCSI IDs
        BA350 storage shelves
        BA353 storage shelves
        BA356 storage shelves
        DEC RAID subsystem controllers
        HSZ10 DEC RAID controllers
        HSZ20 DEC RAID controllers
        HSZ40 DEC RAID controllers
        HSZ50 DEC RAID controllers
        HSZ70 DEC RAID controllers
        requirement

SCSI terminators
        supported

SCSI-2 bus

services
        description of
        description of

setting bus speed
        KZPSA

setting SCSI ID
        DS-TZ89N-TA
        DS-TZ89N-VW
        KZPSA
        TZ885
        TZ88N-TA
        TZ88N-VA

Shared SCSI
        adding devices

shared SCSI buses
        adding
        assigning SCSI IDs
        cable length restrictions
        connecting devices
        connecting devices
        device addresses
        differential
        removing
        requirements
        setting up ASEs
        single-ended
        using SCSI signal converters
        using trilink connectors
        using Y cables

shared storage
        BA350 storage shelf
        BA353 storage shelf
        DEC RAID subsystem array controller
        increasing capacity
        increasing capacity
        non-Ultra BA356 storage shelf
        Ultra BA356 storage shelf

signal converter
        DS-BA35X-DA personality module

signal converters
        connecting and disconnecting
        creating differential bus
        differential I/O module
        differential termination
        DS-BA35X-DA
        extending differential bus length
        fast SCSI bus speed
        overview
        requirement
        requirements
        SBB
        single-ended termination
        standalone
        supported
        terminating
        terminating buses with
        termination
        termination
        using in ASE
        using in ASE

single-ended SCSI buses
        description of

single-ended transmission
        definition

Small Computer System Interconnect
        See SCSI

storage shelves
        adding
        BA350
        BA353
        BA356
        removing
        requirements
        setting up
        supported

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

T

tape service
        description of
        description of

terminating the shared bus

termination resistors
        KZPSA

trilink connectors
        connecting devices with
        requirement
        supported
        terminating bus with

TruCluster Software Products
        MEMORY CHANNEL
        TruCluster Available Server Software
        TruCluster Production Server Software

TZ88
TZ88
        versions

TZ885
TZ885
        cabling
        setting SCSI ID

TZ88N-TA
        cabling
        setting SCSI ID

TZ88N-VA
        cabling
        setting SCSI ID

TZ89
TZ89

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

U

Ultra BA356 storage shelf
        preparing

UltraSCSI BA356
        fast narrow SCSI drives
        fast wide SCSI drives
        personality module (DS-BA35X-DA)
        power supply

UltraSCSI host adapater
        host input connector
        with non-UltraSCSI BA356
        with UltraSCSI BA356

unshielded twisted pair
        See UTP

upgrade
        DWZZA

user-defined service
        description of
        description of

UTP

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

V

Very High Density Cable Interconnect
        See VHDCI

VHDCI
        HSZ70 host connector
        mnemonics defined

Click letter for quick access:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Y

Y cables
        connecting devices with


[Contents] [Top of Index] [Help]